Brand Name: | SZDXZH |
Model Number: | H1KL |
MOQ: | 1 pcs |
Packaging Details: | Woodcase/ Paper box |
Payment Terms: | T/T |
Net Weight (Standard Machine) | 4.1kg |
---|---|
Battery Voltage | 36V |
Dimensions (mm) | 282 × 145 × 220 |
Power Range: 1K VA
Working Mode: Single input and single output, double conversion online operation.
Applications: Government, finance, communications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, and power industries.
Model H1KL Specifications | |
---|---|
Phase | Single-phase grounding |
Capacity | 1000 VA / 800 W |
Input | |
Voltage Range | 110-300VAC at 50% load 160-280VAC at 100% load |
Frequency Range | 40Hz - 70Hz |
Power Factor | ≥0.99 |
Output | |
Output Voltage | 200/208/220/230/240VAC |
Voltage Range (Battery Mode) | ±1% |
Frequency Range (Battery Mode) | 50Hz ±0.25Hz or 60Hz ±0.3Hz |
Waveform (Battery Mode) | Pure sine wave |
Operating Conditions: 0-40°C at 20-90% relative humidity (non-condensing)
Noise Level: Less than 50dBA at 1 meter distance
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC via RS-232/USB
Optional SNMP card available for network management
*Output power reduction applies in constant voltage/frequency mode or when output voltage is set to 208VAC
*Standard models do not support redundant parallel operation
*200/208/220/230/240VAC output available on extended runtime models only
![]() |
Brand Name: | SZDXZH |
Model Number: | H1KL |
MOQ: | 1 pcs |
Packaging Details: | Woodcase/ Paper box |
Payment Terms: | T/T |
Net Weight (Standard Machine) | 4.1kg |
---|---|
Battery Voltage | 36V |
Dimensions (mm) | 282 × 145 × 220 |
Power Range: 1K VA
Working Mode: Single input and single output, double conversion online operation.
Applications: Government, finance, communications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, and power industries.
Model H1KL Specifications | |
---|---|
Phase | Single-phase grounding |
Capacity | 1000 VA / 800 W |
Input | |
Voltage Range | 110-300VAC at 50% load 160-280VAC at 100% load |
Frequency Range | 40Hz - 70Hz |
Power Factor | ≥0.99 |
Output | |
Output Voltage | 200/208/220/230/240VAC |
Voltage Range (Battery Mode) | ±1% |
Frequency Range (Battery Mode) | 50Hz ±0.25Hz or 60Hz ±0.3Hz |
Waveform (Battery Mode) | Pure sine wave |
Operating Conditions: 0-40°C at 20-90% relative humidity (non-condensing)
Noise Level: Less than 50dBA at 1 meter distance
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC via RS-232/USB
Optional SNMP card available for network management
*Output power reduction applies in constant voltage/frequency mode or when output voltage is set to 208VAC
*Standard models do not support redundant parallel operation
*200/208/220/230/240VAC output available on extended runtime models only