Send Message
Good price  online

products details

Home > Products >
High Frequency UPS
>
High Frequency UPS Single Input Single Output Double Conversion Online Operation

High Frequency UPS Single Input Single Output Double Conversion Online Operation

Brand Name: SZDXZH
Model Number: H10K
MOQ: 1 pcs
Price: Negotiable
Packaging Details: Woodcase/ Paper box
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Net Weight (Standard Machine):
55kg
Battery Voltage:
192V
Size:
442*190*688
Name:
High Frequency UPS
Peremeter:
Customized
Coloer:
Black Painted
Supply Ability:
10000pcs/month
Highlight:

double conversion high frequency ups

,

double conversion ups uninterruptible power supply

Product Description
High Frequency UPS Single Input Single Output Double Conversion Online Operation
 
 
Product Introduction / Introduction
 

Power Range: 10K VA

Working mode: single input and single output, double conversion online operation.

Application scope: Widely used in various industries such as government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, medical care, energy and electricity, etc.

 

Features:

·True online double conversion
·Microprocessor control ensures high reliability
·Input power factor correction
·Output power factor can reach 0.8
·Wide mains input range (110 V – 300 V)
·Efficient frequency conversion mode
·Generator compatible
·Optional exquisite SNMP card can be perfectly monitored alone or with USB, RS232
·Simple operation control through the display, and comprehensive display monitoring UPS status
·ECO mode provides energy saving effect
·Emergency power off (EPO)
·Models above 6K use DSP technology, built-in maintenance bypass switch (optional)
·Smart battery charging design extends battery life and performance
·Built-in isolation transformer (optional)

 

Technical Parameters

model H 10 K
Phase Single-phase grounding
capacity 10000 VA / 8000 W
enter
Voltage range 110 -300VAC at 50% load
176-300 VAC at 100% load
Frequency range 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power Factor ≧0.99
Output
Output voltage 208/220/230/240VAC
Voltage range (battery mode) ± 1%
Frequency range (synchronous correction range) 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency range (battery mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Surge ratio 3:01
Harmonic distortion ≦ 3% THD (Linear Load)
≦5% THD (non-linear load )
Conversion time AC to DC 0ms
Inverter to Bypass 0ms
Waveform (Battery Mode) Pure sine wave
efficiency
Mains mode 93 %
Battery Mode 91 %
Battery
Standard Machine Battery Model 12V / 9AH
quantity 16
Maximum charging current Default: 1.0A ± 10%, Max.: 2.0A ± 10%
Long-acting machine Battery Model Depends on battery configuration
quantity 16-20 (adjustable)**
Maximum charging current 1A/2A/4A/6A (adjustable, 6A only applies to 16 batteries)
Appearance
LCD or LED display Load size, Battery capacity, AC mode, Battery mode, Bypass mode, Fault indication
Dimensions
Standard Machine Dimensions, depth x width x height (mm) 442 x 190 x 688
Net weight (kg) 65
Long-lasting models Dimensions, depth x width x height (mm) 442 x 190 x 318
Net weight (kg) 15
Usage Environment
Temperature and humidity Relative humidity 0-95 % and temperature 0- 40°C (non-condensing)
noise Less than 5-8 dBA @ 1 meter
Control Management
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power management supports SNMP management and network management

*When 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 80%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 80%. When
6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 60%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 90%.
*The above commonly sold models do not support redundant parallel operation.
*200/208/220/230/240VAC is only applicable to long-term machines (200VAC is only applicable to 1-3KVA)

——UPS power solution service provider——

High Frequency UPS Single Input Single Output Double Conversion Online Operation 0 

Products Details

Home > Products >
High Frequency UPS
>
High Frequency UPS Single Input Single Output Double Conversion Online Operation

High Frequency UPS Single Input Single Output Double Conversion Online Operation

Brand Name: SZDXZH
Model Number: H10K
MOQ: 1 pcs
Price: Negotiable
Packaging Details: Woodcase/ Paper box
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Brand Name:
SZDXZH
Model Number:
H10K
Net Weight (Standard Machine):
55kg
Battery Voltage:
192V
Size:
442*190*688
Name:
High Frequency UPS
Peremeter:
Customized
Coloer:
Black Painted
Minimum Order Quantity:
1 pcs
Price:
Negotiable
Packaging Details:
Woodcase/ Paper box
Delivery Time:
15-25 days
Payment Terms:
T/T
Supply Ability:
10000pcs/month
Highlight:

double conversion high frequency ups

,

double conversion ups uninterruptible power supply

Product Description
High Frequency UPS Single Input Single Output Double Conversion Online Operation
 
 
Product Introduction / Introduction
 

Power Range: 10K VA

Working mode: single input and single output, double conversion online operation.

Application scope: Widely used in various industries such as government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, medical care, energy and electricity, etc.

 

Features:

·True online double conversion
·Microprocessor control ensures high reliability
·Input power factor correction
·Output power factor can reach 0.8
·Wide mains input range (110 V – 300 V)
·Efficient frequency conversion mode
·Generator compatible
·Optional exquisite SNMP card can be perfectly monitored alone or with USB, RS232
·Simple operation control through the display, and comprehensive display monitoring UPS status
·ECO mode provides energy saving effect
·Emergency power off (EPO)
·Models above 6K use DSP technology, built-in maintenance bypass switch (optional)
·Smart battery charging design extends battery life and performance
·Built-in isolation transformer (optional)

 

Technical Parameters

model H 10 K
Phase Single-phase grounding
capacity 10000 VA / 8000 W
enter
Voltage range 110 -300VAC at 50% load
176-300 VAC at 100% load
Frequency range 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power Factor ≧0.99
Output
Output voltage 208/220/230/240VAC
Voltage range (battery mode) ± 1%
Frequency range (synchronous correction range) 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency range (battery mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Surge ratio 3:01
Harmonic distortion ≦ 3% THD (Linear Load)
≦5% THD (non-linear load )
Conversion time AC to DC 0ms
Inverter to Bypass 0ms
Waveform (Battery Mode) Pure sine wave
efficiency
Mains mode 93 %
Battery Mode 91 %
Battery
Standard Machine Battery Model 12V / 9AH
quantity 16
Maximum charging current Default: 1.0A ± 10%, Max.: 2.0A ± 10%
Long-acting machine Battery Model Depends on battery configuration
quantity 16-20 (adjustable)**
Maximum charging current 1A/2A/4A/6A (adjustable, 6A only applies to 16 batteries)
Appearance
LCD or LED display Load size, Battery capacity, AC mode, Battery mode, Bypass mode, Fault indication
Dimensions
Standard Machine Dimensions, depth x width x height (mm) 442 x 190 x 688
Net weight (kg) 65
Long-lasting models Dimensions, depth x width x height (mm) 442 x 190 x 318
Net weight (kg) 15
Usage Environment
Temperature and humidity Relative humidity 0-95 % and temperature 0- 40°C (non-condensing)
noise Less than 5-8 dBA @ 1 meter
Control Management
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power management supports SNMP management and network management

*When 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 80%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 80%. When
6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 60%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 90%.
*The above commonly sold models do not support redundant parallel operation.
*200/208/220/230/240VAC is only applicable to long-term machines (200VAC is only applicable to 1-3KVA)

——UPS power solution service provider——

High Frequency UPS Single Input Single Output Double Conversion Online Operation 0