Send Message
Good price  online

products details

Home > Products >
High Frequency UPS
>
1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output

Brand Name: SZDXZH
Model Number: DX11 H1KVA-10KVA
MOQ: 1 pcs
Price: Negotiable
Packaging Details: Woodcase/ Paper box
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Certification:
CE,UL
Net Weight (Standard Machine):
9.8kg
Battery Voltage:
24V
Size:
282*145*220
Supply Ability:
10000pcs/month
Highlight:

1K VA High Frequency Tower UPS

,

Single Phase Tower UPS

,

Single Input UPS Battery Backup Equipment

Product Description
 
Product Introduction / Introduction

Power Range: 1K VA

Working mode: single input and single output, double conversion online operation.

Application scope: Widely used in various industries such as government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, medical care, energy and electricity, etc.

 

Features:

· True online double conversion
· Microprocessor control ensures high reliability
· Input power factor correction
· Output power factor can reach 0.8
· Wide mains input range (110 V – 300 V)
· Efficient frequency conversion mode
· Generator compatible
· Optional exquisite SNMP card can be perfectly monitored alone or with USB, RS232
· Simple operation control through the display, and comprehensive display monitoring UPS status
· ECO mode provides energy saving effect
· Emergency power off (EPO)
· Models above 6K use DSP technology, built-in maintenance bypass switch (optional)
· Smart battery charging design extends battery life and performance
· Built-in isolation transformer (optional)

Technical Parameters

model H1K
Phase Single-phase grounding
capacity 1000 VA / 800 W
enter
Voltage range 110 -300VAC at 50% load
160 -280 VAC at 100% load
Frequency range 40Hz ~ 70Hz
Power Factor ≧0.99
Output
Output voltage 200/208/220/230/240VAC
Voltage range (battery mode) ± 1%
Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz
Frequency range (battery mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Surge ratio 3:01
Harmonic distortion ≦ 3% THD (Linear Load)
≦6% THD (non-linear load )
Conversion time AC to DC 0ms
Inverter to Bypass 4 ms (under standard conditions)
Waveform (Battery Mode) Pure sine wave
efficiency
Mains mode 88%
Battery Mode 83%
Battery
Standard Machine Battery Model 12V / 9AH
quantity 2
Maximum charging current 1.0A (max)
Long-acting machine Battery Model Depends on battery configuration
quantity 3
Maximum charging current 1A/2A/4A/6A (adjustable)
Appearance
LCD or LED display Load size, Battery capacity, AC mode, Battery mode, Bypass mode, Fault indication
Dimensions
Standard Machine Dimensions, depth x width x height (mm) 282 X 145 X 220
Net weight (kg) 9.8
Long-lasting models Dimensions, depth x width x height (mm) 282 X 145 X 220
Net weight (kg) 4.1
Usage Environment
Temperature and humidity Relative humidity 20-90% and temperature 0- 40°C (non-condensation)
noise Less than 50dBA @ 1 meter
Control Management
Smart RS-232 / USB 支持 Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power management supports SNMP management and network management

* When 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 80%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 80%. When
6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 60%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 90%.
* The above commonly sold models do not support redundant parallel operation.
* 200/208/220/230/240VAC is only applicable to long-term machines (200VAC is only applicable to 1-3KVA)

 

model 11-H1KVA 11-H2KVA 11-H3KVA 11-H6KVA 11-H10KVA
Phase Single in, single out
capacity 1000VA/800W 2000VA/1600W 3000VA/2400W 6000VA/4800W 10000VA/8000W
IN
INPUT VOLTAGE 200/208/220/230/240VAC 208/220/230/240VAC
Voltage range 110-300VAC At 50% load;160-280VAC At 100% load 110-300VAC At 50% load;
176-300VAC At 100% load
Frequency range 40Hz-70Hz 46Hz-54HzOR56Hz-64Hz
Power factor 100% load≥0.99
OUT
Output voltage 200/208/220/230/240VAC 208/220/230/240VAC
Voltage stabilization accuracy (battery mode) ±1%
Frequency range (synchronous correction range) 47Hz-53Hz or 57Hz-63Hz 46Hz-54Hz or 56Hz-64Hz
Frequency range (battery mode) 50Hz±0.25Hz or 60Hz±0.3Hz 50Hz±0.1Hz or 60Hz±0.1Hz
Peak factor 3:01
Harmonic distortion ≤3% TDH(Linear Load);≤6% TDH(Nonlinear load) ≤3% TDH(Linear load);
≤5% TDH(Nonlinear load)
Overload capacity Commercial power mode:100%~110%:10min;110%~130%:1min;>130%:1s
Battery Mode:100%~110%:30s;110%~130%:10s;>130%:1s
Change time Municipal electric battery 0ms 0ms
Reverse to bypass 4ms(Under standard conditions) 0ms
Waveform (battery mode) Pure sine wave
Efficiency
Commercial power mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
Battery
Standard machine(S) model No 12V 7AH
quantity 2 4 6 12 16
Maximum charging current 1.0A(MAX) Presets:1.0A±10%,MAX:2.0A±10%
Long lasting machine(L) model No Depends on the user
quantity 3 6 8 16-20sections (adjustable)
Maximum charging current 1A/2A/4A/6A (adjustable) 1A/2A/4A/6A(adjustable,6A is only suitable for 16 batteries)
Display Description
LCD display Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication
warning sound
Battery Mode Every 4 seconds, it rings
Low battery Every 1 seconds, it rings
overload Every 1 seconds, it rings
fault Continuous ringing
physical property
Standard machine size:D*W*H(MM) 282*145*220 397*145*220 421*190*318 369*190*688 442*190*668
weight KG 8.7 15.7 24.6 51 65
Long lasting machine size:D*W*H(MM) 282*145*220 397*145*220 369*190*318 440*190*318
weight KG 4.1 6.9 7.4 12 15
Usage environment
Temperature and humidity Relative humidity 20-95% and 0-40 ℃ (non condensing) Relative humidity 0-95% and 0-40 ℃ (non condensing)
noise Less than 50dB@1 rice Less than 55dB@1 rice Less than 58dB@1 rice
sup-control
IntelligenceRS-232/USB SupportWindows2000/2003/XP/Vista/2008,Windows7/8,Linux and MAC
Optional SNMP card Power management supports SNMP management and network management
When 1-3 K VA UPS is set to constant voltage and frequency mode, the output power will be reduced by 20%. When the output voltage of UPS is set to 208 VA C, the output power will be reduced by 20%
When 6/10 K VA UPS is set to constant voltage and frequency mode, the output power will be reduced by 40%,
When the output voltage of UPS is set to 208 VA C, the output power will be reduced by 10%
When the number of internal batteries in the 6/10 K VA U PS is changed to 16-19, the machine will reduce its output according to the following formula: P=P r a t i n g X (N/20 x 100%) • If the machine is installed at an altitude exceeding 1000 meters, the output power will decrease by 1% for every 100 meters increase
If there are any changes to the current product specifications, no further notice will be given

——UPS power solution service provider——

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 0 

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 11K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 21K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 31K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 41K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 51K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 6

Products Details

Home > Products >
High Frequency UPS
>
1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output

Brand Name: SZDXZH
Model Number: DX11 H1KVA-10KVA
MOQ: 1 pcs
Price: Negotiable
Packaging Details: Woodcase/ Paper box
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Brand Name:
SZDXZH
Certification:
CE,UL
Model Number:
DX11 H1KVA-10KVA
Net Weight (Standard Machine):
9.8kg
Battery Voltage:
24V
Size:
282*145*220
Minimum Order Quantity:
1 pcs
Price:
Negotiable
Packaging Details:
Woodcase/ Paper box
Delivery Time:
15-25 days
Payment Terms:
T/T
Supply Ability:
10000pcs/month
Highlight:

1K VA High Frequency Tower UPS

,

Single Phase Tower UPS

,

Single Input UPS Battery Backup Equipment

Product Description
 
Product Introduction / Introduction

Power Range: 1K VA

Working mode: single input and single output, double conversion online operation.

Application scope: Widely used in various industries such as government, finance, communications, education, transportation, meteorology, radio and television, industrial and commercial taxation, medical care, energy and electricity, etc.

 

Features:

· True online double conversion
· Microprocessor control ensures high reliability
· Input power factor correction
· Output power factor can reach 0.8
· Wide mains input range (110 V – 300 V)
· Efficient frequency conversion mode
· Generator compatible
· Optional exquisite SNMP card can be perfectly monitored alone or with USB, RS232
· Simple operation control through the display, and comprehensive display monitoring UPS status
· ECO mode provides energy saving effect
· Emergency power off (EPO)
· Models above 6K use DSP technology, built-in maintenance bypass switch (optional)
· Smart battery charging design extends battery life and performance
· Built-in isolation transformer (optional)

Technical Parameters

model H1K
Phase Single-phase grounding
capacity 1000 VA / 800 W
enter
Voltage range 110 -300VAC at 50% load
160 -280 VAC at 100% load
Frequency range 40Hz ~ 70Hz
Power Factor ≧0.99
Output
Output voltage 200/208/220/230/240VAC
Voltage range (battery mode) ± 1%
Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz
Frequency range (battery mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Surge ratio 3:01
Harmonic distortion ≦ 3% THD (Linear Load)
≦6% THD (non-linear load )
Conversion time AC to DC 0ms
Inverter to Bypass 4 ms (under standard conditions)
Waveform (Battery Mode) Pure sine wave
efficiency
Mains mode 88%
Battery Mode 83%
Battery
Standard Machine Battery Model 12V / 9AH
quantity 2
Maximum charging current 1.0A (max)
Long-acting machine Battery Model Depends on battery configuration
quantity 3
Maximum charging current 1A/2A/4A/6A (adjustable)
Appearance
LCD or LED display Load size, Battery capacity, AC mode, Battery mode, Bypass mode, Fault indication
Dimensions
Standard Machine Dimensions, depth x width x height (mm) 282 X 145 X 220
Net weight (kg) 9.8
Long-lasting models Dimensions, depth x width x height (mm) 282 X 145 X 220
Net weight (kg) 4.1
Usage Environment
Temperature and humidity Relative humidity 20-90% and temperature 0- 40°C (non-condensation)
noise Less than 50dBA @ 1 meter
Control Management
Smart RS-232 / USB 支持 Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power management supports SNMP management and network management

* When 1-3KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 80%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 80%. When
6/10KVA UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 60%, and when the output voltage of the UPS is set to 208VAC, the output power will be reduced by 90%.
* The above commonly sold models do not support redundant parallel operation.
* 200/208/220/230/240VAC is only applicable to long-term machines (200VAC is only applicable to 1-3KVA)

 

model 11-H1KVA 11-H2KVA 11-H3KVA 11-H6KVA 11-H10KVA
Phase Single in, single out
capacity 1000VA/800W 2000VA/1600W 3000VA/2400W 6000VA/4800W 10000VA/8000W
IN
INPUT VOLTAGE 200/208/220/230/240VAC 208/220/230/240VAC
Voltage range 110-300VAC At 50% load;160-280VAC At 100% load 110-300VAC At 50% load;
176-300VAC At 100% load
Frequency range 40Hz-70Hz 46Hz-54HzOR56Hz-64Hz
Power factor 100% load≥0.99
OUT
Output voltage 200/208/220/230/240VAC 208/220/230/240VAC
Voltage stabilization accuracy (battery mode) ±1%
Frequency range (synchronous correction range) 47Hz-53Hz or 57Hz-63Hz 46Hz-54Hz or 56Hz-64Hz
Frequency range (battery mode) 50Hz±0.25Hz or 60Hz±0.3Hz 50Hz±0.1Hz or 60Hz±0.1Hz
Peak factor 3:01
Harmonic distortion ≤3% TDH(Linear Load);≤6% TDH(Nonlinear load) ≤3% TDH(Linear load);
≤5% TDH(Nonlinear load)
Overload capacity Commercial power mode:100%~110%:10min;110%~130%:1min;>130%:1s
Battery Mode:100%~110%:30s;110%~130%:10s;>130%:1s
Change time Municipal electric battery 0ms 0ms
Reverse to bypass 4ms(Under standard conditions) 0ms
Waveform (battery mode) Pure sine wave
Efficiency
Commercial power mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
Battery
Standard machine(S) model No 12V 7AH
quantity 2 4 6 12 16
Maximum charging current 1.0A(MAX) Presets:1.0A±10%,MAX:2.0A±10%
Long lasting machine(L) model No Depends on the user
quantity 3 6 8 16-20sections (adjustable)
Maximum charging current 1A/2A/4A/6A (adjustable) 1A/2A/4A/6A(adjustable,6A is only suitable for 16 batteries)
Display Description
LCD display Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication
warning sound
Battery Mode Every 4 seconds, it rings
Low battery Every 1 seconds, it rings
overload Every 1 seconds, it rings
fault Continuous ringing
physical property
Standard machine size:D*W*H(MM) 282*145*220 397*145*220 421*190*318 369*190*688 442*190*668
weight KG 8.7 15.7 24.6 51 65
Long lasting machine size:D*W*H(MM) 282*145*220 397*145*220 369*190*318 440*190*318
weight KG 4.1 6.9 7.4 12 15
Usage environment
Temperature and humidity Relative humidity 20-95% and 0-40 ℃ (non condensing) Relative humidity 0-95% and 0-40 ℃ (non condensing)
noise Less than 50dB@1 rice Less than 55dB@1 rice Less than 58dB@1 rice
sup-control
IntelligenceRS-232/USB SupportWindows2000/2003/XP/Vista/2008,Windows7/8,Linux and MAC
Optional SNMP card Power management supports SNMP management and network management
When 1-3 K VA UPS is set to constant voltage and frequency mode, the output power will be reduced by 20%. When the output voltage of UPS is set to 208 VA C, the output power will be reduced by 20%
When 6/10 K VA UPS is set to constant voltage and frequency mode, the output power will be reduced by 40%,
When the output voltage of UPS is set to 208 VA C, the output power will be reduced by 10%
When the number of internal batteries in the 6/10 K VA U PS is changed to 16-19, the machine will reduce its output according to the following formula: P=P r a t i n g X (N/20 x 100%) • If the machine is installed at an altitude exceeding 1000 meters, the output power will decrease by 1% for every 100 meters increase
If there are any changes to the current product specifications, no further notice will be given

——UPS power solution service provider——

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 0 

1K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 11K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 21K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 31K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 41K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 51K VA High Frequency Tower UPS Battery Backup Equipment Single Input And Output 6